# Rebooting the GN production machine(s)
I needed to add the hard disks in the BIOS to make them visible - one of the annoying aspects of these Dell machines. First on Tux02 I cheched the borg backups to see if we have a recent copy of MariaDB, GN2 etc. The DB is from 2 days ago and the genotypes of GN2 are a week old (because of a permission problem). I'll add a copy by hand of both - an opportunity to test the new 10Gbs router.
# Tasks
Before rebooting
On Tux02:
* [X] Check backups of DB and services
* [X] Copy trees between machines
On both:
* [X] Check network interface definitions (what happens on reboot)
* [X] Check IPMI access - should get serial login
# Info
## Routing
On tux02 eno2d1 is the 10Gbs network interface. Unfortunately I can't get it to connect at 10Gbs with Tux01 because the latter is using that port for the outside world.
Playing with 10Gbs on Tux01 sent the hardware in a tail spin, what to think of this solution on
```
bnxt_en 0000:01:00.1 (unnamed net_device) (uninitialized): Error (timeout: 500015) msg {0x0 0x0} len:0
Solution was to power down the server(s) and *remove* power cords for 5 minutes.
```
=> https://www.dell.com/community/PowerEdge-Hardware-General/Critical-network-bnxt-en-module-crashes-on-14G-servers/td-p/6031769
The Linux kernel shows some fixes that are not on Tux01 yet
=> https://lkml.org/lkml/2021/2/17/970
In our case a simple reboot worked, fortunately.
|